• Description
  • Features
  • Sweep Chart Configuration
  • Limit Calculation
  • Weld Schedules
  • Fault Data
 

ADMSTAT Plus™ is a product of Computer Weld Technology, Inc. and is designed to operate in conjunction with our ADM IV™ monitoring system.  The program provides a serial communications program, which is used to communicate with the ADM IV and to collect weld data. 

It provides graphical functions, which permits the user to view and analyze stored welding data.  The program provides a full function, user configurable ASCII terminal program, which can be used to configure all of the ADM IV functions. It provides weld data collection routines that allow the user to collect run-time weld data and store this data for future analysis. 

A statistical function allows the user to generate basic Process Control Limits for a specified weld schedule based on stored weld data files. The ADM IV control limits can be edited and include a Weld Setup specification sheet, which is used to save process specific user information for the current weld schedule.  A graphical analysis function is included to provide easy analysis of stored weld data files and to generate graphical reports.

 
   

"Pull-down"menu screens

   
Tool Bar "Speed Buttons"
   
Control Bar "Command Buttons"
   
Real time on screen sweep graphs, displayed simultaneously, for up to four user definable parameters
   
Graph "Zoom" capability during data collection or data review phase
   
Can be interfaced with customer supplied software
   
ASCII terminal program
   
Graphical and statistical analysis of stored weld data
   
Multiple weld schedule identification
   
Calculate, display, edit and store Arc Data Monitor limits
   
Specific user definable "Fault Messages"
   
ASCII data exporting capability
   
 
Sweep Chart Configuration
 
 
Setup what you perfer to be shown on the sweep charts.
 
Simultaneously collect and Display Real-Time Sweep Graph of Weld Data
 
 
The statistical function allows the user to calculate basic process control limits for a specific weld schedule based on the stored weld data, edit those calculated limits as required and down load them to the ADM IV™.
 
Weld Schedule Edit
Other features included are a weld setup specification sheet used to record specific operational and process data for the current weld schedule, and the graph function which provides the capability to easily review and export the archived weld data.
 
Fault Data Display
 
The Fault Data Display allows the user to display stored weld data which indicates the date, time, weld number, schedule and faulted data for each fault condition detected. Easily scroll through all fault summaries and display status for each enabled parameters. The summaries can be printed to provided a hard copy of the faulted welds.
 
 
 
 
 
 
 
  Please disable browser pop-up blockers for documents on www.cweldtech.com  
 
 
  Note - All documents are in an Adobe PDF file format.  
 
 
 
 
 
     
 

 

 

 

 

Product Specifications

 

 

 

  • System Requirements
 
   
150mhz Pentium™ or higher microprocessor
 
Windows®98/ME/2000/XP or Windows NT® 3.51 or later platforms
   
24 Megs minimum for Windows® 98/ME, 32 Megs for Windows® NT/2000/XP
   
25 Megs of available hard drive space
   
Minimum SVGA graphics, XVGA recommended
   
RS-232 serial port
   
 
 
   
 
   

 

Copyright 1994-2009 Computer Weld Technology, Inc. - All rights reserved.